We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Gas chromatograph.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Gas chromatograph - Company Ranking(25 companies in total)

Last Updated: Aggregation Period:Feb 04, 2026〜Mar 03, 2026
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
<Column Oven> Temperature Range: Room Temperature +4 to 450 ℃ Dimensions: 280(W) × 175(D) × 280(H) mm Number of Program Steps: 20 step... Sample Injection Unit: Split/Splitless Injection Unit ×1 Detector - Thermal Ionization Detector (FTD) ×1 - Flame Photometric Detector ...
Sample injection part: Split/Splitless injection unit ×1 Detector: Hydrogen flame ionization detector (FID) ×1 Auto injector: AOC-20i ×1... <Column Oven> Temperature Range: Room Temperature +10 to 400 ℃ Dimensions: 250(W) × 90(D) × 250(H) mm Number of Program Steps: 20 step...
<Detector (FID)> Temperature range: Up to 450 ℃ Minimum detection amount: 1.2 pgC/s (dodecane) Dynamic range: 10^7 <Column oven> Temperature... <Configuration> Sample Injection Section: Split/Splitless Injection Unit ×2 Detector: Hydrogen Flame Ionization Detector (FID) ×2 Measuremen...
---

---

---
  1. Featured Products
    Capillary Gas Chromatograph (FTD, FPD) (GC)Capillary Gas Chromatograph (FTD, FPD) (GC)
    overview
    <Column Oven> Temperature Range: Room Temperature +4 to 450 ℃ Dimensions: 280(W) × 175(D) × 280(H) mm Number of Program Steps: 20 step...
    Application/Performance example
    Sample Injection Unit: Split/Splitless Injection Unit ×1 Detector - Thermal Ionization Detector (FTD) ×1 - Flame Photometric Detector ...
    Energy-saving capillary gas chromatograph (FID)Energy-saving capillary gas chromatograph (FID)
    overview
    Sample injection part: Split/Splitless injection unit ×1 Detector: Hydrogen flame ionization detector (FID) ×1 Auto injector: AOC-20i ×1...
    Application/Performance example
    <Column Oven> Temperature Range: Room Temperature +10 to 400 ℃ Dimensions: 250(W) × 90(D) × 250(H) mm Number of Program Steps: 20 step...
    Capillary column gas chromatograph (FID) (GC)Capillary column gas chromatograph (FID) (GC)
    overview
    <Detector (FID)> Temperature range: Up to 450 ℃ Minimum detection amount: 1.2 pgC/s (dodecane) Dynamic range: 10^7 <Column oven> Temperature...
    Application/Performance example
    <Configuration> Sample Injection Section: Split/Splitless Injection Unit ×2 Detector: Hydrogen Flame Ionization Detector (FID) ×2 Measuremen...